V8446

Bell-shaped luminaires

  • Enclosure opens without tools
  • Rapid mounting using Vulkan Patent System (VPS)
  • Low glare thanks to large optics surface
  • Efficient thermal management thanks to in-built heat sink

System power
11,1 W – 36 W

Luminous flux
1.643 lm – 5.077 lm

Colour temperature
1800 K / 2700 K / 3000 K / 4000 K

Ingress protection
IP65

BoardsWmAlmKCRI
2x LED28,2 W550 mA4.129 lm4000KRa >70
2x LED23,0 W450 mA3.469 lm4000KRa >70
2x LED33,5 W650 mA4.772 lm4000KRa >70
2x LED32,0 W600 mA4.448 lm4000KRa >70
2x LED18,3 W350 mA2.729 lm4000KRa >70
2x LED13,5 W250 mA2.052 lm4000KRa >70
2x LED20,7 W400 mA3.092 lm4000KRa >70
2x LED36,0 W700 mA5.077 lm4000KRa >70
2x LED25,7 W500 mA3.804 lm4000KRa >70
2x LED11,1 W200 mA1.643 lm4000KRa >70
2x LED16,0 W300 mA2.390 lm4000KRa >70

General Specifications

Enclosure:
  • Acrylic outer casing (PMMA), clear or structured version

Optics:

  • Available with asymmetrical, symmetrical & axially symmetrical light distribution; developed for the standard-compliant illumination of streets, paths and squares according to DIN-EN 13201.
  • The following optics can be used: optic O1, optic O2, optic O3, optic O7, optic O8, optic O9

Optional:

  • An element can be installed to reduce the luminance within the optical system on the building side
  • For optic overview, please press "Photometric reports" button

Electrical Specifications

LED technology:
  • Versions with one or two LED boards, each with 8 high-power-LEDs
  • Aluminium core PCB for optimum thermal management
  • Integrated thermal sensor to protect the LED unit against over-temperature
  • Electronic LED driver on carrier plate with plug connection for electrical isolation, if required can be interchanged with ease

Overvoltage protection:

  • Integrated; surge voltage resistance of 6kV (L-N) (10kV on request), 10kV (L/N earth)

Additional Specifications

Housing:
  • Single-part luminaire housing constructed from dimensionally stable and corrosion-resistant aluminium

Attachment:

  • Pole attachment with VPS quick mounting system

Light regulation / Lightmanagement:

  • Constant Lumen Management (CLM); autonomous performance reduction for operation in networks without a control line (Light Regulation Autarkic - LRA); performance reduction by switching off a control line (Light Regulation Twin - LRT)