V308X
Pole top- and side mounted luminaire
- Luminaire family with four sizes for a uniform appearance across all application situations
- Easy maintenance via tool-free quick-release fasteners, detentable housing with partition plug and separately removable electronic support carrier
- Very light weight housing for easy one-man installation
- Spigot for universal top and side mounting
System power
11 W – 278 W
Luminous flux
1.518 lm – 37.520 lm
Colour temperature
3000 K / 4000 K
Ingress protection
IP66
Boards | W | mA | lm | K | CRI |
---|---|---|---|---|---|
V3083 | 115,0 W | 300 mA | 17.636 lm | 4000K | Ra >70 |
V3083 | 214,0 W | 550 mA | 30.768 lm | 4000K | Ra >70 |
V3083 | 153,0 W | 400 mA | 23.188 lm | 4000K | Ra >70 |
V3083 | 134,0 W | 350 mA | 20.260 lm | 4000K | Ra >70 |
V3083 | 96,0 W | 250 mA | 15.008 lm | 4000K | Ra >70 |
V3083 | 256,0 W | 650 mA | 35.644 lm | 4000K | Ra >70 |
V3083 | 78,0 W | 200 mA | 12.140 lm | 4000K | Ra >70 |
V3083 | 173,0 W | 450 mA | 25.888 lm | 4000K | Ra >70 |
V3083 | 278,0 W | 700 mA | 37.520 lm | 4000K | Ra >70 |
V3083 | 235,0 W | 600 mA | 33.016 lm | 4000K | Ra >70 |
V3083 | 194,0 W | 500 mA | 28.140 lm | 4000K | Ra >70 |
V3081 | 21,0 W | 200 mA | 3.035 lm | 4000K | Ra >70 |
V3081 | 30,0 W | 300 mA | 4.409 lm | 4000K | Ra >70 |
V3082 | 128,0 W | 650 mA | 17.822 lm | 4000K | Ra >70 |
V3082 | 87,0 W | 450 mA | 12.944 lm | 4000K | Ra >70 |
V3080 | 18,0 W | 350 mA | 2.532 lm | 4000K | Ra >70 |
V3080 | 31,0 W | 600 mA | 4.127 lm | 4000K | Ra >70 |
V3080 | 16,0 W | 300 mA | 2.204 lm | 4000K | Ra >70 |
V3080 | 21,0 W | 400 mA | 2.898 lm | 4000K | Ra >70 |
V3080 | 34,0 W | 650 mA | 4.456 lm | 4000K | Ra >70 |
V3080 | 28,0 W | 550 mA | 3.846 lm | 4000K | Ra >70 |
V3080 | 26,0 W | 500 mA | 3.518 lm | 4000K | Ra >70 |
V3082 | 77,0 W | 400 mA | 11.594 lm | 4000K | Ra >70 |
V3082 | 58,0 W | 300 mA | 8.818 lm | 4000K | Ra >70 |
V3082 | 39,0 W | 200 mA | 6.070 lm | 4000K | Ra >70 |
V3082 | 117,0 W | 600 mA | 16.508 lm | 4000K | Ra >70 |
V3082 | 107,0 W | 550 mA | 15.384 lm | 4000K | Ra >70 |
V3082 | 48,0 W | 250 mA | 7.504 lm | 4000K | Ra >70 |
V3082 | 67,0 W | 350 mA | 10.130 lm | 4000K | Ra >70 |
V3082 | 97,0 W | 500 mA | 14.070 lm | 4000K | Ra >70 |
V3080 | 11,0 W | 200 mA | 1.518 lm | 4000K | Ra >70 |
V3080 | 36,0 W | 700 mA | 4.690 lm | 4000K | Ra >70 |
V3080 | 14,0 W | 250 mA | 1.876 lm | 4000K | Ra >70 |
V3081 | 70,0 W | 700 mA | 9.380 lm | 4000K | Ra >70 |
V3081 | 55,0 W | 550 mA | 7.692 lm | 4000K | Ra >70 |
V3081 | 65,0 W | 650 mA | 8.911 lm | 4000K | Ra >70 |
V3081 | 26,0 W | 250 mA | 3.752 lm | 4000K | Ra >70 |
V3081 | 45,0 W | 450 mA | 6.472 lm | 4000K | Ra >70 |
V3081 | 50,0 W | 500 mA | 7.035 lm | 4000K | Ra >70 |
V3081 | 40,0 W | 400 mA | 5.797 lm | 4000K | Ra >70 |
V3081 | 35,0 W | 350 mA | 5.065 lm | 4000K | Ra >70 |
V3082 | 139,0 W | 700 mA | 18.760 lm | 4000K | Ra >70 |
V3081 | 60,0 W | 600 mA | 8.254 lm | 4000K | Ra >70 |
General Specifications
Enclosure:- Flat single-pane tempered safety glass, partially printed on the inside in grey
Maintenance:
- Easy opening due to quick-locks, electronic ballast on gear tray can be removed separately
Optics:
- Lighting of roads that complies with DIN-EN 13201; lens optics made from PMMA in multi-layer-technology optics O1 - major thoroughfares; O3 - minor thoroughfares; O4 - narrow roads, cycle paths and walkways; O7 - thoroughfares and residential streets
Electrical Specifications
LED technology:- Number of LEDs: 12 (V3080), 24 (V3081), 48 (V3082), 72 (V3083)
- High-quality LED modules with high-efficiency high-power LEDs
- Aluminium core printed circuit board for optimal thermal management
- Integrated, electronically controlled temperature monitoring Framed LED module to reduce scattering losses to a minimum
Monitoring
- Thermal monitoring integrated in the operating device
Overvoltage protection:
- Integrated; surge voltage resistance of 6kV (L-N) (10kV with PRII on request), 10kV (L/N-earth)
Additional Specifications
Housing:- Powder-coated, die-cast aluminium
- Spigot Ø 48 / 60 / 76mm for pole top- and side mounted luminaire
Light regulation:
- Constant Lumen Management (CLM); autonomous performance reduction for operation in networks without a control line (Light Regulation Autarkic - LRA); performance reduction by switching off a control line (Light Regulation Twin - LRT)
- Digital communication with DALI
- Radio-controlled Light Management System (LMS) with monitoring, error messages, motion control and other features